Take Action With Our Guide to Rheem Water Heater Error Codes
Posted in Hot Water Heater Repairs , on November 19, 2026
A Rheem error code identifies the condition detected by the water heater’s control system, but it does not always identify the exact failed part. If you need water heater repair in Hollywood, record the code and describe what the unit was doing when it appeared. A licensed plumber in Hollywood can compare that information with the model's technical documentation. Contact an emergency plumber in Hollywood if the heater is leaking significantly, smells like gas, or presents an immediate safety concern.
Check the Model Before Interpreting a Code
Rheem manufactures several types of gas, electric, tank, tankless, and power-vent water heaters. Their codes are not interchangeable. A number displayed on one model may mean something different on another.
The codes discussed below come from Rheem’s technical bulletin for PowerVent ESII water heaters equipped with Honeywell electronic controls. Before taking action, check the model information on your unit and consult its corresponding manual.
Ignition and Flame-Related Codes
Several codes in Rheem’s PowerVent bulletin relate to ignition or flame detection:
- Error 10 indicates a hard lockout. Possible causes listed by Rheem include low gas pressure, electrode buildup, damaged igniter wiring, or restrictions affecting the pilot or burner supply.
- Error 11 means the heater failed its permitted ignition trials.
- Error 12 indicates a low flame signal while the control continues operating.
- Error 13 means the flame was lost during a heating cycle.
- Error 14 indicates that the control sensed flame at an unexpected point in the operating sequence.
These conditions involve combustion and gas-control components. Homeowners should not disassemble the burner, adjust gas pressure, or replace gas valves themselves. Turn the unit off if you smell gas, leave the immediate area, and follow the gas utility's emergency instructions.
Temperature and Control Faults
Error 31 indicates that the system entered a high-temperature limit lockout. Error 89 relates to a thermal-well or temperature-sensor fault. Error 15 indicates an electronics fault, while Error 93 points to a detected gas-valve fault.
A code may appear because of a faulty sensor, damaged control, wiring issue, or another condition affecting the system. Clearing the display without correcting the cause may only result in the code returning. Arrange water heater repair in Hollywood if the heater remains locked out, overheats, or repeatedly displays the same fault.
Pressure-Switch and Venting Codes
On the model covered by Rheem's bulletin:
- Error 44 means the pressure switch failed closed.
- Error 45 indicates that a pressure switch or limit opened repeatedly.
- Error 46 means the pressure switch failed to close.
These codes may be associated with blocked tubing, venting restrictions, switch problems, blower operation, wiring, or installation conditions. Do not remove venting or bypass a safety switch. A plumber in Hollywood can inspect the system without defeating components intended to protect the property and its occupants.
Flammable-Vapor Sensor Codes
Error 47 indicates a flammable-vapor sensor lockout, while Error 49 indicates a sensor, wiring, or control fault. Do not assume the warning is harmless. Avoid creating sparks or operating nearby switches if gasoline or another flammable substance may be present.
What Information Should You Give Your Plumber?
Before booking service, note:
- The complete model and serial information
- The displayed number or flash pattern
- Whether the heater is leaking
- Whether the blower, burner, or pilot operates
- When the problem began
- Whether the code returns after the unit stops
Broward Plumbing provides diagnostic service for water-heater problems throughout Hollywood and Broward County. If the heater is leaking, our guide to emergency water heater leaks explains immediate steps that may help limit damage while you wait for professional service.